HP 578230-B21 HP mart Array P410 8 port SAS RAID Controller, Part No. 578230-B21 at lowest prices at itdevicesonline.ca Call Now: (403) 800-4390 All Prices in Canadian Dollars.
I have an HP ProLiant DL180 G5 server with a Smart Array E200 RAID controller. The RAID controller is refusing to recognize inserted drives as an array. The story so far..
This server (our file server) needed an upgrade. It started with 8 x 250GB drives:
The plan was to replace the RAID5 array and hot spare with a RAID10 array composed of much larger disks. The old drives would be untouched in case any recovery was needed. The following process was used:
This procedure worked as expected. But some data was missed in the last backup, so I need to recover data from the drives in the original array. Here's what I've done:
At this point, I get the following error:
I had assumed that the RAID metadata stored on the disks would be sufficient to bring the old RAID array back online, but that doesn't seem to be the case. I can hardly believe that the drives would be rendered inaccessible as soon as they are removed from the original RAID controller. Is there anything I can do to access the data on the old drives? If not, which RAID controllers support this, so I know what to buy in the future?
I have already contacted HP support, and they were unable to help. Their recommendation was to recreate the RAID array and restore the data, but that doesn't really help my situation.
The removed drives still have the RAID metadata on them. When you went to step #3 in the first drive replacement process; Boot up the server and acknowledge errors about failed drives
, did you DELETE the removed array/logical drive or just mark it as failed? That's probably the source of the problem here.
When you brought up the system with your old drives, you should have again deleted the new data logical drive either in the BIOS raid utility or with the Smartstart/DL180 Setup Array Configuration utility and let the controller detect the array/logical drive. Football manager 2012 tactics download.
Try this. Boot up with the new drives removed. Go into the BIOS or DL180 setup disk Array Config and delete the RAID 1+0 array. Then boot with your old drives and see if they're detected. Get the data you need. Remove the old drives. Delete the array. Insert your new drives. Let the controller discover the new array. Restore your data..
Keep this HP Smart Array controller users guide handy.http://h20564.www2.hpe.com/hpsc/doc/public/display?docId=c01608507
Oof, this one should have been obvious.
The E200 controller was still expecting to see the drives from the RAID10 array. When I powered up without the data drives inserted, it gave a warning about failed drives instead of an error, then let me continue into the OS. Once in the OS, I was able to access the Array Configuration Utility to 'delete' the RAID10 configuration. On the next reboot, the RAID5 array reappeared as expected.
I'm not sure if this question should be deleted, since I answered it myself so quickly. But I think it could be useful for other people using HP RAID controllers.
If not, which RAID controllers support this, so I know what to buy in the future?
I've had great experiences with 3ware controllers in situations like this. I've pulled full arrays from 6000 series controllers and used them on 7000 series controllers. I've intentionally jumbled the drives in an array and it picked up the changes without issue. The 3ware (tw_cli) utility is much more user friendly than either the HP (hpacucli) or the LSI (MegaMgr/MegaCLI) utility. (It should be noted that LSI bought 3ware last year. I hope they continue with the (almost) awesome 3ware utility.)
Hal leonard bass method cd download. American Musical Supply reserves the right to correct pricing and/or product specifications in the event of typographical errors found in our print catalog or on our website.